On this page
Section 4.9Site preparation

Electrical: Ritual 4-Person

Circuit specs for the SW80 heater on the 4-Person — 240V single-phase, 40A 2-pole breaker, 8 AWG copper wire.

The Ritual 4-Person uses the Harvia "The Wall" SW80 heater rated at 8.0 kW, sized for the larger cabin volume.

Circuit requirements

SpecificationValue
Heater modelHarvia SW80
Heater power8.0 kW
Voltage240V single-phase
Breaker40A double-pole, dedicated circuit
Wire gauge8 AWG copper
ConnectionHardwired (no plug-in option)
Isolation switchRecommended near the unit

For your electrician

  • Run a dedicated 40A double-pole circuit on 240V single-phase
  • Use 8 AWG copper conductor
  • Hardwire to the heater per the Harvia wiring diagram included with the unit
  • Install an isolation switch near the sauna for service access
  • Outdoor installations: use direct-burial-rated cable in conduit, buried 18-24 inches deep per local code
  • House the control unit in a dry/weatherproof location — never inside the sauna cabin

The Harvia heater nameplate references 230V (CE/EU standard). It runs identically on US 240V split-phase service — voltage tolerance is well within manufacturer spec. The 4-Person's 40A draw is the most common breaker size for premium DTC outdoor saunas in the 8 kW class.

Last updated May 10, 2026